Temperature sensor, thermocouple (K-type), magnetic type. Temperature sensor, thermocouple (K-type), magnetic type.

A surface temperature sensor with a magnet incorporated into the measurement contact point.

  • Class 2
  • RoHS2 compliant

The sensor can be attached using a magnet and is easy to remove. It is recommended for temperature measurement on surfaces made of magnetic metal, such as molds.

[Features]
■ Temperature sensing element only: 400℃ / Operating limit: 350℃
■ Tolerance: Class 2 (±2.5℃ or ±0.75%) Wire diameter: 0.32mm.

[Application]
■ Temperature sensor (sold separately) compatible with the monoOne®-120/200 temperature controller. Can also be used with other temperature control devices.

*This product is designed to be used with a temperature controller (sold separately).

  • In stock

Temperature sensor, thermocouple (K-type), magnetic type. Order your thermocouple (K-type) magnetic temperature sensor here.

Orders can be placed for a single unit. We will propose the optimal solution tailored to your desired heating temperature, the object to be heated, and the installation environment.

There are reasons why many companies, educational institutions, and research organizations choose us.
That's because they are passionate professionals who always go to the site and find solutions .
From single-item production to mass production, we can help you solve your heat-related manufacturing challenges.

The answer is always found on the scene.

We are committed to on-site work .
We will solve the temperature problem .

Product Features

Attach the sensor using a magnet.

This surface temperature sensor incorporates a magnet at the measurement contact point. The sensor can be easily attached and removed using the magnet. It is recommended for temperature measurement of surfaces made of magnetic metal, such as molds.

Since it is a K-type thermocouple, it can be used with commercially available temperature controllers if the type matches.
If you have a device that doesn't fit your needs or you don't have a temperature controller, you can purchase the monoOne® digital temperature controller along with it and use them together.

The principle of thermocouples

A thermocouple utilizes the Seebeck effect, which creates a closed circuit using two different metal wires. When the two junctions at the ends are kept at different temperatures, a current flows corresponding to the temperature difference, and when one end is opened, a thermoelectric force corresponding to the temperature difference is generated.
Because the relationship between temperature and thermoelectric power is clear, temperature can be measured by connecting a DC voltmeter between two terminals created by opening one junction and measuring the thermoelectric power. A device that uses this principle to measure temperature, combining two different metals, is called a thermocouple.

Safety precautions regarding insulated thermocouple wires

Please read this carefully and follow the instructions to ensure safe use.

caveat

*Ignoring this warning and mishandling the product may result in death or serious injury.

  • • Insulated thermocouple wires are not electrical wires. Do not use them for general wiring. This may cause electric shock, leakage, or fire. Insulated thermocouple wires, which use a special metal with high resistance as the conductor, will experience overcurrent if the same current is passed through them as in general electrical wires that use soft copper wire as the conductor, which can lead to leakage and fire.

Precautions

Ignoring this warning and mishandling the product may result in injury or property damage.

  • Do not use in applications subject to repeated bending, twisting, pulling, abrasion, or vibration. This may cause wire breakage or insulation deterioration. Insulated thermocouple wires are for fixed wiring and cannot withstand repeated bending, twisting, pulling, abrasion, or vibration. This may cause wire breakage or damage/deterioration of the insulation.
  • Do not use in places where it may get wet or in humid places. This may cause electrical leakage or short circuits. Braided insulation and wound insulation made of glass fiber, silica glass fiber, or ceramic fiber are not waterproof and may cause electrical leakage or short circuits. Tape-wrapped insulation such as PTFE tape, polyimide tape, or mica tape is not waterproof and may cause electrical leakage or short circuits.
  • The information provided is subject to change without notice.

Product Specifications

Thermocouple (K-type) Magnetic Type

Temperature sensing element only: 400°C / Operating temperature: 350°C, Tolerance: Class 2 (±2.5°C or ±0.75%), Wire diameter: 0.32mm

Product Code L(m)
TH-8007-2 2.0

Additional options

You can change the thermocouple wire from glass-coated to stainless steel-coated, or attach miniature connectors to the terminals.

When changing the thermocouple wire to a SUS coating.

Adding a SUS coating (shield) improves durability even in harsh environments and usage conditions.
Furthermore, it is designed to be highly resistant to electrical noise.
Product code: TH-8007-2-S

When changing the terminal to a miniature connector

By changing the terminal to a miniature connector, it can be easily attached to the monoOne+ series. There is no need for screws, and removal is easy.
Product code: TH-8007-2-C

2つのご注文方法

ORDER MADE HEATER

1.受注製作品をご希望の方はじめての
ご注文の方も

1つからオーダーメイド。
ご要望を高い精度で実現。

スリーハイの製品の大半はオーダーメイドのカスタマイズ製品です。お客様へのカウンセリングや現場訪問をもとに、1000種類以上あるスリーハイ製品の中から最もご希望に合う製品をご提案しています。

特注・オーダーメイドの詳細を見る

お電話・FAXでのお問い合わせ

0120-972-128
FAXでのお問い合わせ045-590-5571

ウェブからのお問い合わせ

お問い合わせ
ONLINE STORE

2.標準品のご購入をご希望の方在庫品は当日12時までの
ご注文で当日配送

豊富な標準品の在庫を
常にご用意しています。

スリーハイではオーダーメイト製作以外にも標準品の在庫を多数ご用意しております。目的の製品が決まっている方や2度目のご注文の方はオンラインストアからご購入ください。型番からの検索も可能です。

標準品一覧へ

オンラインストア

製品名で検索

Frequently Asked Questions

To use the heater safely,
In addition to the heater unit itself, a temperature controller and temperature sensor are required.

新規会員登録 10%OFFクーポンプレゼント
Back to top of page