Temperature sensor, thermocouple (K-type), sheet type.


This thermocouple is formed on an insulating sheet and is suitable for measuring surface temperature. It is a sheet-type thermocouple that can be attached to the surface of an object to measure its surface temperature quickly and accurately.
[Features]
■ Fast response time and adhesive/stickable.
■ Fluoropolymer coating: Operating limit: 200℃, tolerance: Class 2 (±2.5℃ or ±0.75%).
*The maximum operating temperature depends on the properties of the adhesive and insulating material.
[Application]
■ Temperature sensor (sold separately) compatible with the monoOne®-120/200 temperature controller. Can also be used with other temperature control devices.
■ Ideal for experimental temperature measurement, etc.
*This product is designed to be used with a temperature controller (sold separately).
*Once our stock of RoHS-compliant products (Y-terminal blue tube) runs out, we will gradually switch to RoHS2-compliant products (Y-terminal white tube). (The image shown is of the RoHS2-compliant product.)

Order your temperature sensor thermocouple (K-type) sheet here.There are reasons why many companies, educational institutions, and research organizations choose us.
That's because they are passionate professionals who always go to the site and find solutions .
From single-item production to mass production, we can help you solve your heat-related manufacturing challenges.

The answer is always found on the scene.
We are committed to on-site work .
We will solve the temperature problem .
This thermocouple is formed on an insulating sheet and is suitable for measuring surface temperature. It is a sheet-type thermocouple that can be attached to the surface of an object to measure its surface temperature quickly and accurately.
It features a fast response time, is attachable (adhesive tape for attachment must be provided by the customer), and is relatively inexpensive. It is ideal for experimental temperature measurement and other applications.
Since it is a K-type thermocouple, it can be used with commercially available temperature controllers if the type matches.
If you have a device that doesn't fit your needs or you don't have a temperature controller, you can purchase the monoOne® digital temperature controller along with it and use them together.
The principle of thermocouplesA thermocouple utilizes the Seebeck effect, which creates a closed circuit using two different metal wires. When the two junctions at the ends are kept at different temperatures, a current flows corresponding to the temperature difference, and when one end is opened, a thermoelectric force corresponding to the temperature difference is generated.
Because the relationship between temperature and thermoelectric power is clear, temperature can be measured by connecting a DC voltmeter between two terminals created by opening one junction and measuring the thermoelectric power. A device that uses this principle to measure temperature, combining two different metals, is called a thermocouple.
Please attach or press the device onto the surface of the object to be measured using adhesive. It can be reused multiple times if attached with heat-resistant tape. The maximum operating temperature depends on the properties of the adhesive and insulating material; if this issue is resolved, it can withstand overloads of 300°C or higher. Response time depends on the adhesion, but is approximately 50mm, and 2-5 milliseconds for bare elements. For applications requiring particularly fast response times, or when the object to be measured is an insulating material, the insulating sheet (bakelite-impregnated paper) can be removed before use.
*The front edge of the sheet can be attached with either side facing outwards. (Yellow part: polyimide, white part: fiberglass)
*Please note that if an air layer forms between the object being measured and the sheet thermocouple, the response speed will be significantly slower.

Please read this carefully and follow the instructions to ensure safe use.
*Ignoring this warning and mishandling the product may result in death or serious injury.

Ignoring this warning and mishandling the product may result in injury or property damage.

Operating temperature limit: 200°C, tolerance: Class 2 (±2.5°C or ±0.75%)
| Product Code | L(m) |
|---|---|
| TH-8297-1 | 1.0 |
| TH-8297-3 | 3.0 |
| TH-8297-10 | 10.0 |
*Due to the manufacturing process, there may be some color variations, but this does not affect performance.
はじめての1つからオーダーメイド。
ご要望を高い精度で実現。
スリーハイの製品の大半はオーダーメイドのカスタマイズ製品です。お客様へのカウンセリングや現場訪問をもとに、1000種類以上あるスリーハイ製品の中から最もご希望に合う製品をご提案しています。
特注・オーダーメイドの詳細を見る
豊富な標準品の在庫を
常にご用意しています。

スリーハイではオーダーメイト製作以外にも標準品の在庫を多数ご用意しております。目的の製品が決まっている方や2度目のご注文の方はオンラインストアからご購入ください。型番からの検索も可能です。
Yes, it is possible.
Many of our customers consider ordering just one item. Of course, we also handle mass production.
Broadly speaking, there are two types: analog (suitable for rough temperature control) and digital (suitable for high-precision temperature control). We recommend the low-cost digital models "monoOne®+Ao" and "monoOne®-120/T" (MonoOne®).
While we retain customer data, we don't usually include it. If you would like it included, please request it when placing your order.
Please Inquiry. We will check the condition to see if it can be repaired.
To use the heater safely,