Temperature sensor, thermocouple (K-type), sheet type. Temperature sensor, thermocouple (K-type), sheet type.

Excellent thermal response! Ideal for measuring surface temperature.

  • Class 2
  • RoHS2 compliant

This thermocouple is formed on an insulating sheet and is suitable for measuring surface temperature. It is a sheet-type thermocouple that can be attached to the surface of an object to measure its surface temperature quickly and accurately.

[Features]
■ Fast response time and adhesive/stickable.
■ Fluoropolymer coating: Operating limit: 200℃, tolerance: Class 2 (±2.5℃ or ±0.75%).
*The maximum operating temperature depends on the properties of the adhesive and insulating material.

[Application]
■ Temperature sensor (sold separately) compatible with the monoOne®-120/200 temperature controller. Can also be used with other temperature control devices.
■ Ideal for experimental temperature measurement, etc.

*This product is designed to be used with a temperature controller (sold separately).

*Once our stock of RoHS-compliant products (Y-terminal blue tube) runs out, we will gradually switch to RoHS2-compliant products (Y-terminal white tube). (The image shown is of the RoHS2-compliant product.)

  • In stock

Temperature sensor, thermocouple (K-type), sheet type. Order your temperature sensor thermocouple (K-type) sheet here.

Orders can be placed for a single unit. We will propose the optimal solution tailored to your desired heating temperature, the object to be heated, and the installation environment.

There are reasons why many companies, educational institutions, and research organizations choose us.
That's because they are passionate professionals who always go to the site and find solutions .
From single-item production to mass production, we can help you solve your heat-related manufacturing challenges.

The answer is always found on the scene.

We are committed to on-site work .
We will solve the temperature problem .

Product Features

Sold individually! Excellent thermal response! For measuring surface temperature.

This thermocouple is formed on an insulating sheet and is suitable for measuring surface temperature. It is a sheet-type thermocouple that can be attached to the surface of an object to measure its surface temperature quickly and accurately.
It features a fast response time, is attachable (adhesive tape for attachment must be provided by the customer), and is relatively inexpensive. It is ideal for experimental temperature measurement and other applications.

Since it is a K-type thermocouple, it can be used with commercially available temperature controllers if the type matches.
If you have a device that doesn't fit your needs or you don't have a temperature controller, you can purchase the monoOne® digital temperature controller along with it and use them together.

The principle of thermocouples

A thermocouple utilizes the Seebeck effect, which creates a closed circuit using two different metal wires. When the two junctions at the ends are kept at different temperatures, a current flows corresponding to the temperature difference, and when one end is opened, a thermoelectric force corresponding to the temperature difference is generated.
Because the relationship between temperature and thermoelectric power is clear, temperature can be measured by connecting a DC voltmeter between two terminals created by opening one junction and measuring the thermoelectric power. A device that uses this principle to measure temperature, combining two different metals, is called a thermocouple.

How to use

Please attach or press the device onto the surface of the object to be measured using adhesive. It can be reused multiple times if attached with heat-resistant tape. The maximum operating temperature depends on the properties of the adhesive and insulating material; if this issue is resolved, it can withstand overloads of 300°C or higher. Response time depends on the adhesion, but is approximately 50mm, and 2-5 milliseconds for bare elements. For applications requiring particularly fast response times, or when the object to be measured is an insulating material, the insulating sheet (bakelite-impregnated paper) can be removed before use.

*The front edge of the sheet can be attached with either side facing outwards. (Yellow part: polyimide, white part: fiberglass)
*Please note that if an air layer forms between the object being measured and the sheet thermocouple, the response speed will be significantly slower.

Safety precautions regarding insulated thermocouple wires

Please read this carefully and follow the instructions to ensure safe use.

caveat

*Ignoring this warning and mishandling the product may result in death or serious injury.

  • • Insulated thermocouple wires are not electrical wires. Do not use them for general wiring. This may cause electric shock, leakage, or fire. Insulated thermocouple wires, which use a special metal with high resistance as the conductor, will experience overcurrent if the same current is passed through them as in general electrical wires that use soft copper wire as the conductor, which can lead to leakage and fire.

Precautions

Ignoring this warning and mishandling the product may result in injury or property damage.

  • Do not use in applications subject to repeated bending, twisting, pulling, abrasion, or vibration. This may cause wire breakage or insulation deterioration. Insulated thermocouple wires are for fixed wiring and cannot withstand repeated bending, twisting, pulling, abrasion, or vibration. This may cause wire breakage or damage/deterioration of the insulation.
  • Do not use in places where it may get wet or in humid places. This may cause electrical leakage or short circuits. Braided insulation and wound insulation made of glass fiber, silica glass fiber, or ceramic fiber are not waterproof and may cause electrical leakage or short circuits. Tape-wrapped insulation such as PTFE tape, polyimide tape, or mica tape is not waterproof and may cause electrical leakage or short circuits.
  • The information provided is subject to change without notice.

Product Specifications

Thermocouple (K-type) sheet type (fluororesin coated)

Operating temperature limit: 200°C, tolerance: Class 2 (±2.5°C or ±0.75%)

Product Code L(m)
TH-8297-1 1.0
TH-8297-3 3.0
TH-8297-10 10.0

*Due to the manufacturing process, there may be some color variations, but this does not affect performance.

2つのご注文方法

ORDER MADE HEATER

1.受注製作品をご希望の方はじめての
ご注文の方も

1つからオーダーメイド。
ご要望を高い精度で実現。

スリーハイの製品の大半はオーダーメイドのカスタマイズ製品です。お客様へのカウンセリングや現場訪問をもとに、1000種類以上あるスリーハイ製品の中から最もご希望に合う製品をご提案しています。

特注・オーダーメイドの詳細を見る

お電話・FAXでのお問い合わせ

0120-972-128
FAXでのお問い合わせ045-590-5571

ウェブからのお問い合わせ

お問い合わせ
ONLINE STORE

2.標準品のご購入をご希望の方在庫品は当日12時までの
ご注文で当日配送

豊富な標準品の在庫を
常にご用意しています。

スリーハイではオーダーメイト製作以外にも標準品の在庫を多数ご用意しております。目的の製品が決まっている方や2度目のご注文の方はオンラインストアからご購入ください。型番からの検索も可能です。

標準品一覧へ

オンラインストア

製品名で検索

Frequently Asked Questions

To use the heater safely,
In addition to the heater unit itself, a temperature controller and temperature sensor are required.

新規会員登録 10%OFFクーポンプレゼント
Back to top of page