Temperature sensor, duplex (tip welded) type (Class 2 glass coated) Temperature sensor
Duplex (tip-welded) type (Class 2 glass coating)

For environments requiring high heat resistance of 250°C to 350°C

  • Class 2
  • RoHS2 compliant

Duplex thermocouples are thermocouples in which the thermocouple wires are coated with a material such as fluororesin or glass, and are used as is without being enclosed in a protective tube.

■ Connect to a temperature controller or data logger, etc., and use it for temperature control, temperature measurement, etc. of the object.

*This product is designed to be used with a temperature controller (sold separately).

*A ring terminal can be attached to the tip. For those who prefer screw fastening. (The model number will have "-M" at the end.)

Temperature sensor, duplex (tip welded) type (Class 2 glass coated) Order your temperature sensor (duplex type, tip welded, Class 2, glass coated) here.

Orders can be placed for a single unit. We will propose the optimal solution tailored to your desired heating temperature, the object to be heated, and the installation environment.

There are reasons why many companies, educational institutions, and research organizations choose us.
That's because they are passionate professionals who always go to the site and find solutions .
From single-item production to mass production, we can help you solve your heat-related manufacturing challenges.

The answer is always found on the scene.

We are committed to on-site work .
We will solve the temperature problem .

Product Features

For environments requiring high heat resistance of 250°C to 350°C

Duplex thermocouples are thermocouples in which the thermocouple wires are coated with a material such as fluororesin or glass, and are used as is without being enclosed in a protective tube.
This product has a welded tip, and the temperature is detected at that point.
*When using the heater, for safety reasons, please be sure to use both the temperature sensor and temperature controller together.

Since it is a K-type thermocouple, it can be used with commercially available temperature controllers if the type matches.
If you have a device that doesn't fit your needs or you don't have a temperature controller, you can purchase the monoOne® digital temperature controller along with it and use them together.

The principle of thermocouples

A thermocouple utilizes the Seebeck effect, which creates a closed circuit using two different metal wires. When the two junctions at the ends are kept at different temperatures, a current flows corresponding to the temperature difference, and when one end is opened, a thermoelectric force corresponding to the temperature difference is generated.
Because the relationship between temperature and thermoelectric power is clear, temperature can be measured by connecting a DC voltmeter between two terminals created by opening one junction and measuring the thermoelectric power. A device that uses this principle to measure temperature, combining two different metals, is called a thermocouple.

Safety precautions regarding insulated thermocouple wires

Please read this carefully and follow the instructions to ensure safe use.

caveat

*Ignoring this warning and mishandling the product may result in death or serious injury.

  • • Insulated thermocouple wires are not electrical wires. Do not use them for general wiring. This may cause electric shock, leakage, or fire. Insulated thermocouple wires, which use a special metal with high resistance as the conductor, will experience overcurrent if the same current is passed through them as in general electrical wires that use soft copper wire as the conductor, which can lead to leakage and fire.

Precautions

Ignoring this warning and mishandling the product may result in injury or property damage.

  • Do not use in applications subject to repeated bending, twisting, pulling, abrasion, or vibration. This may cause wire breakage or insulation deterioration. Insulated thermocouple wires are for fixed wiring and cannot withstand repeated bending, twisting, pulling, abrasion, or vibration. This may cause wire breakage or damage/deterioration of the insulation.
  • Do not use in places where it may get wet or in humid places. This may cause electrical leakage or short circuits. Braided insulation and wound insulation made of glass fiber, silica glass fiber, or ceramic fiber are not waterproof and may cause electrical leakage or short circuits. Tape-wrapped insulation such as PTFE tape, polyimide tape, or mica tape is not waterproof and may cause electrical leakage or short circuits.
  • The information provided is subject to change without notice.

Product Specifications

Thermocouple (K-type) Duplex (Glass-coated)

Operating temperature limit: 250°C, Tolerance: Class 2 (±2.5°C or ±0.75%), Wire diameter: 0.32 mm

Product Code L(m)
TH-1202-1 (TH-8162-1 successor) 1.0
TH-1202-2 (TH-8162-2 successor) 2.0
TH-1202-3 (TH-8162-3 successor) 3.0
TH-1202-5 (TH-8162-5 successor) 5.0
TH-1202-10 (TH-8162-10 successor) 10.0
TH-1202-20 (TH-8162-20 successor) 20.0

Thermocouple (K-type) Duplex (Glass-coated)

Operating temperature limit: 350°C, Tolerance: Class 2 (±2.5°C or ±0.75%), Wire diameter: 0.32 mm

Product Code L(m)
TH-1302-1 (TH-8294-1 successor) 1.0
TH-1302-2 (TH-8294-2 successor) 2.0
TH-1302-3 (TH-8294-3 successor) 3.0
TH-1302-5 (TH-8294-5 successor) 5.0
TH-1302-10 (TH-8294-10 successor) 10.0
TH-1302-20 (TH-8294-20 successor) 20.0
constituent materials
+ legs -leg
Nickel and chromium-based alloy (Chromel CR) Nickel-based alloy (Alumel, AL)
characteristics

(JIS C 1602-1995)

class Temperature range Tolerance
Class 1 -40℃ or higher and below +375℃ ±1.5℃
375℃ or higher, less than 1000℃ ±0.004・|t|
Class 2 -40℃ or higher and below +333℃ ±2.5℃
333℃ or higher, less than 1200℃ ±0.0075・|t|
Class 3 -167℃ or higher and +40℃ or lower ±2.5℃
-200℃ or higher, -167℃ or lower ±0.015・|t|
Normal operating temperature limit and overheating limit temperature of thermocouple wires

(JIS C 1602-1995)

Wire diameter (mm)    
0.2 Regular use (℃) 300
Overheating (℃) 400
0.32 Regular use (℃) 400
Overheating (℃) 500
0.65 Regular use (℃) 650
Overheating (℃) 850
Insulating material and coating material temperature
Insulated thermocouple wire Insulator/Sheath Maximum operating temperature Minimum operating temperature
material ℃ ℃
General use Heat-resistant vinyl 90 -20
Heat resistant Silicone rubber 180 -55
Fluoropolymer FEP 200 -250
Fluoropolymer PFA 260 -200
Fluororesin 260 -250
glass fiber 250 -
Silica glass fiber 500 -
Ceramic fiber 1000 -
identification
insulator outer covering
+ -
red white blue

2つのご注文方法

ORDER MADE HEATER

1.受注製作品をご希望の方はじめての
ご注文の方も

1つからオーダーメイド。
ご要望を高い精度で実現。

スリーハイの製品の大半はオーダーメイドのカスタマイズ製品です。お客様へのカウンセリングや現場訪問をもとに、1000種類以上あるスリーハイ製品の中から最もご希望に合う製品をご提案しています。

特注・オーダーメイドの詳細を見る

お電話・FAXでのお問い合わせ

0120-972-128
FAXでのお問い合わせ045-590-5571

ウェブからのお問い合わせ

お問い合わせ
ONLINE STORE

2.標準品のご購入をご希望の方在庫品は当日12時までの
ご注文で当日配送

豊富な標準品の在庫を
常にご用意しています。

スリーハイではオーダーメイト製作以外にも標準品の在庫を多数ご用意しております。目的の製品が決まっている方や2度目のご注文の方はオンラインストアからご購入ください。型番からの検索も可能です。

標準品一覧へ

オンラインストア

製品名で検索

Frequently Asked Questions

To use the heater safely,
In addition to the heater unit itself, a temperature controller and temperature sensor are required.

新規会員登録 10%OFFクーポンプレゼント
Back to top of page