The answer is always found on the scene.
We are committed to on-site work .
We will solve the temperature problem .
Temperature sensor

Duplex thermocouples are thermocouples in which the thermocouple wires are coated with a material such as fluororesin or glass, and are used as is without being enclosed in a protective tube.
■ Connect to a temperature controller or data logger, etc., and use it for temperature control, temperature measurement, etc. of the object.
*This product is designed to be used with a temperature controller (sold separately).
*A ring terminal can be attached to the tip. For those who prefer screw fastening. (The model number will have "-M" at the end.)
Order your temperature sensor (duplex type, tip welded, Class 2, glass coated) here.There are reasons why many companies, educational institutions, and research organizations choose us.
That's because they are passionate professionals who always go to the site and find solutions .
From single-item production to mass production, we can help you solve your heat-related manufacturing challenges.

The answer is always found on the scene.
We are committed to on-site work .
We will solve the temperature problem .
Duplex thermocouples are thermocouples in which the thermocouple wires are coated with a material such as fluororesin or glass, and are used as is without being enclosed in a protective tube.
This product has a welded tip, and the temperature is detected at that point.
*When using the heater, for safety reasons, please be sure to use both the temperature sensor and temperature controller together.
Since it is a K-type thermocouple, it can be used with commercially available temperature controllers if the type matches.
If you have a device that doesn't fit your needs or you don't have a temperature controller, you can purchase the monoOne® digital temperature controller along with it and use them together.
The principle of thermocouplesA thermocouple utilizes the Seebeck effect, which creates a closed circuit using two different metal wires. When the two junctions at the ends are kept at different temperatures, a current flows corresponding to the temperature difference, and when one end is opened, a thermoelectric force corresponding to the temperature difference is generated.
Because the relationship between temperature and thermoelectric power is clear, temperature can be measured by connecting a DC voltmeter between two terminals created by opening one junction and measuring the thermoelectric power. A device that uses this principle to measure temperature, combining two different metals, is called a thermocouple.
Please read this carefully and follow the instructions to ensure safe use.
*Ignoring this warning and mishandling the product may result in death or serious injury.

Ignoring this warning and mishandling the product may result in injury or property damage.

Operating temperature limit: 250°C, Tolerance: Class 2 (±2.5°C or ±0.75%), Wire diameter: 0.32 mm
| Product Code | L(m) |
|---|---|
| TH-1202-1 (TH-8162-1 successor) | 1.0 |
| TH-1202-2 (TH-8162-2 successor) | 2.0 |
| TH-1202-3 (TH-8162-3 successor) | 3.0 |
| TH-1202-5 (TH-8162-5 successor) | 5.0 |
| TH-1202-10 (TH-8162-10 successor) | 10.0 |
| TH-1202-20 (TH-8162-20 successor) | 20.0 |

Operating temperature limit: 350°C, Tolerance: Class 2 (±2.5°C or ±0.75%), Wire diameter: 0.32 mm
| Product Code | L(m) |
|---|---|
| TH-1302-1 (TH-8294-1 successor) | 1.0 |
| TH-1302-2 (TH-8294-2 successor) | 2.0 |
| TH-1302-3 (TH-8294-3 successor) | 3.0 |
| TH-1302-5 (TH-8294-5 successor) | 5.0 |
| TH-1302-10 (TH-8294-10 successor) | 10.0 |
| TH-1302-20 (TH-8294-20 successor) | 20.0 |
| constituent materials |
|
|||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| characteristics |
(JIS C 1602-1995)
|
|||||||||||||||||||||||||||||||||
| Normal operating temperature limit and overheating limit temperature of thermocouple wires |
(JIS C 1602-1995)
|
|||||||||||||||||||||||||||||||||
| Insulating material and coating material temperature |
|
|||||||||||||||||||||||||||||||||
| identification |
|
|||||||||||||||||||||||||||||||||
はじめての1つからオーダーメイド。
ご要望を高い精度で実現。
スリーハイの製品の大半はオーダーメイドのカスタマイズ製品です。お客様へのカウンセリングや現場訪問をもとに、1000種類以上あるスリーハイ製品の中から最もご希望に合う製品をご提案しています。
特注・オーダーメイドの詳細を見る
豊富な標準品の在庫を
常にご用意しています。

スリーハイではオーダーメイト製作以外にも標準品の在庫を多数ご用意しております。目的の製品が決まっている方や2度目のご注文の方はオンラインストアからご購入ください。型番からの検索も可能です。
Yes, it is possible.
Many of our customers consider ordering just one item. Of course, we also handle mass production.
Broadly speaking, there are two types: analog (suitable for rough temperature control) and digital (suitable for high-precision temperature control). We recommend the low-cost digital models "monoOne®+Ao" and "monoOne®-120/T" (MonoOne®).
While we retain customer data, we don't usually include it. If you would like it included, please request it when placing your order.
Please Inquiry. We will check the condition to see if it can be repaired.
To use the heater safely,