monoOne®-200 monoOne®-200
(MONO ONE® 200)

A high-output model capable of 30A output.

  • RoHS2 compliant
  • made in Japan
  • Original Products

Low noise is achieved through temperature control that generates minimal noise and an automatic cooling fan.

■ High capacity of 30A. Sophisticated design.
■ By combining a 2-degree-of-freedom PID control system temperature controller and SSR with a cycle control unit, more precise temperature control with less generated noise can be achieved.
■ The cooling fan automatically operates based on ambient temperature and usage time, suppressing the rise in internal temperature of the device while also providing excellent low-noise performance.
■ Even in the event of unpredictable malfunctions, using the error port allows you to utilize buzzers, flashing lights, and other devices to create a safe work environment.

*Temperature sensor is not included. Please select a temperature sensor suitable for your application.

  • In stock

monoOne®-200 Click here to order monoOne®-200.

Orders can be placed for a single unit. We will propose the optimal solution tailored to your desired heating temperature, the object to be heated, and the installation environment.

There are reasons why many companies, educational institutions, and research organizations choose us.
That's because they are passionate professionals who always go to the site and find solutions .
From single-item production to mass production, we can help you solve your heat-related manufacturing challenges.

The answer is always found on the scene.

We are committed to on-site work .
We will solve the temperature problem .

Product Features

Easy! Safe! And compact!

From turning the power on/off to setting the temperature, it's all done with just one finger!

This is a high-performance, compact temperature controller suitable for everyone from beginners to professionals. We accept orders for single units.

Standard equipment

Error function

Even in the event of unpredictable malfunctions such as heater wire breakage (*) or sensor wire breakage, using an error port allows for the use of buzzers, rotating lights, etc., to create a safe work environment.

*Parameter settings must be configured in advance.

Product Specifications

Model monoOne-200
input Thermocouple (K, J, T, E, L, U, N, R, S, B, W, PL Ⅱ)
Platinum resistance thermometer (Pt100Ω)
Power supply voltage AC100V to 240V (single-phase/three-phase) 50/60Hz
Output format SSR (contactless) voltage output (output voltage depends on power supply voltage)
Output rating 30A or less. *Due to the SSR output, there is a slight leakage current. Please contact us if the current value is 0.2A or less.
Auxiliary output AC250V 3A (resistive load)
Control method 1.2-degrees-of-freedom PID (with auto-tuning)
2. ON/OFF control
Control constants Proportional band: Thermocouple/Side temperature resistance multi-input type: 0.1 to 999.9 (°C)
Control period: 0.5, 1 to 99 seconds
Integration time: 0 to 3999s (seconds)
Adjustable sensitivity thermocouple: Side temperature resistance multi-input type: 0.1 to 999.9 (°C)
Differential time: 0 to 3999s (seconds)
PV correction: -199.9 to 999.9 (°C)
Indication accuracy
thermocouple K −200 ~ 1300 ℃
(±0.3% of the indicated value or ±1°C, whichever is greater) ± 1 digit or less
T,N Below -100°C, the tolerance is ±2°C ±1 digit or less.
U,L ± 2 ℃ ± 1 digit or less
B 400 to 800 ± 3°C or less. No regulations below 400°C.
(±0.3% of the indicated value or ±1°C, whichever is greater) ± 1 digit or less
R,S Below 200℃: ±3℃ ± 1 digit or less
W (±0.3% of the indicated value or ±3°C, whichever is greater) ±1 digit or less
PLⅡ (±0.3% of the indicated value or ±2°C, whichever is greater) ±1 digit or less
Platinum resistance thermometer (Within ±0.3% of the indicated value or ±8°C, whichever is greater) ±1 digit or less
Display section 11-segment digital display and single-emitting display (7-segment display also available)
PV: 15.8mm SV: 9.5mm MV: 6.8mm
Sampling period 250ms
Set value storage Non-volatile memory (write cycles: 1 million)
Short-circuit protection No-fuse circuit breaker
Celsius/Fahrenheit switching display function none
Other features Automatic cooling fan / AC 100V to 200V (single-phase/three-phase)
Multi-power input/cycle control system
Power consumption 25VA or less
Permissible ambient conditions Temperature: 0℃~55℃
Humidity: 25%-85%
Withstand voltage AC1500V for 1 minute
Noise immunity Pulse width 100 ns, 1 μs, 1500 V
Dimensions/Weight 220mm (height) x 220mm (width) x 220mm (depth) (excluding protrusions), approximately 6kg
price monoOne®200: ¥218,000 (excluding tax)

The information provided is subject to change without notice.

2つのご注文方法

ORDER MADE HEATER

1.受注製作品をご希望の方はじめての
ご注文の方も

1つからオーダーメイド。
ご要望を高い精度で実現。

スリーハイの製品の大半はオーダーメイドのカスタマイズ製品です。お客様へのカウンセリングや現場訪問をもとに、1000種類以上あるスリーハイ製品の中から最もご希望に合う製品をご提案しています。

特注・オーダーメイドの詳細を見る

お電話・FAXでのお問い合わせ

0120-972-128
FAXでのお問い合わせ045-590-5571

ウェブからのお問い合わせ

お問い合わせ
ONLINE STORE

2.標準品のご購入をご希望の方在庫品は当日12時までの
ご注文で当日配送

豊富な標準品の在庫を
常にご用意しています。

スリーハイではオーダーメイト製作以外にも標準品の在庫を多数ご用意しております。目的の製品が決まっている方や2度目のご注文の方はオンラインストアからご購入ください。型番からの検索も可能です。

標準品一覧へ

オンラインストア

製品名で検索

Frequently Asked Questions

Catalog Download

What is a temperature controller?

A temperature controller is a device that controls a heater to maintain it at a target temperature.
Based on the temperature readings from the temperature sensor, the system adjusts whether or not to output power to the heater by comparing it to the target temperature.
It plays a very important role in ensuring the safe use of the heater.

Why use a temperature controller?

safety

In the case of heaters that cannot "self-regulate," the temperature will continue to rise to the heater's capacity limit as long as it is connected to the power supply. Therefore, depending on the temperature range, there is a risk of accidents.
A temperature controller is essential for safe use.

quality control

Because it allows for constant temperature control, it is also useful for quality control and other applications.
Furthermore, digital systems are better suited for more precise temperature control.
*Analog systems are not suitable for applications requiring high precision.

To use the heater safely,
In addition to the heater unit itself, a temperature controller and temperature sensor are required.

新規会員登録 10%OFFクーポンプレゼント
Back to top of page